The small dimensions of the gas-tight air heater allow for space-saving installation. If one or more heaters are connected to the compressed air network, it will receive an air flow with high air speeds. The temperature can be controlled electronically. The hot air stream is used in drying processes, welding processes, etc. Due to its robust design, this device is suitable for the most demanding use.
Type PN10
Description
Special features:
- Gas-tight and pressure-resistant
- Reliable protection of the heating element thanks to integrated electronics
- Optional integrated thermocouple
- External activation possible via a controller or PLC (SPS)
- External potentiometer option
- A 3-metre connection cable is standard; a two-pole circuit breaker must be provided on the mains side
- Various voltages, power ratings and special versions available, such as external activation via a controller or PLC (SPS).
ATTENTION!!!
- Observe the minimum air flow rate
- Supply only dry, oil-free air
- The heaters are only suitable for stationary use in plants and machines.
- Improper use of the air heaters may create a fire hazard
- The air heaters are protection class I and must be connected by qualified personnel.
- Follow the operating instructions
Technical specifications
| Item no. | 5201198 | 5201190 | 5201191 | 5201192 | 5201194 | 5201193 | 5201197 |
| Voltage (VAC) | 230 | 230 | 230 | 400 (2Ph) | 400-440 | 400-440 | 400-440 |
| Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Power (kW) | 3.3 | 3.3 | 3.7 | 4.5 | 11.8-14.3 | 11.8-14.3 | 17.0-21.0 |
| Current (A) | 14.4 | 14.4 | 16.1 | 11.2 | 17.1-18.7 | 17.1-18.7 | 25.1-27.6 |
| Max. temperature (ºC) | 650 | 650 | 650 | 650 | 650 | 650 | 600 |
| Min. air flow (l/min.) | 300 | 300 | 270 | 320 | 1100 | 1100 | 1480 |
| Weight (kg) | 4.7 | 4.7 | 16.5 | 16.5 | 24.0 | 24.0 | 24.0 |
| Outlet opening [Ø mm] | 12.7 | 12.7 | 25.4 | 25.4 | 50.8 | 50.8 | 50.8 |
| Protection class | I | I | I | I | I | I | I |
| Dimensions (mm – LxWxH) | 360x170x170 | 360x170x170 | 400x285x285 | 400x285x285 | 520x340x340 | 520x340x340 | 582×340 |
| Conformity mark | C.E. | C.E. | C.E. | C.E. | C.E. | C.E. | C.E. |
| Supply air connection [Ø mm] | 12.7 | 12.7 | 25.4 | 25.4 | 50.8 | 50.8 | 50.8 |
| Max. supply air pressure [bar] | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Additional information
| Modelo | 5201198, 5201190, 5201191, 5201192, 5201194, 5201193, 5201197 |
|---|---|
| Power | 2.0-2.5 Kw |
| Maximum temperature | 600-1112 |
| Min. air flow | 280-1480 l/min |
| Built-in air | No |
| Ordenacion | 20 |